Made in the USA

Model: 53696-S12

53696-S12

500W Proton Rad Hard 100K+® DC-DC Converter Power Supply

Features

RadHard TID >100kRad(Si)
No SEE: LET > 82meV*cm^2/mg
Proton Resistant: No optocouplers used
Completely self contained Thick Film Hybrid DC-DC Converter
Fully Isolated design
External Sync
Inhibit-not function
Power on soft start
Fully Isolated design with magnetically coupled feedback
Reverse Polarity Protection
User adjustable set point
Fully isolated, input to output
No Optocouplers

Specifications

Input: 28 VDC
Input Range (Continuous): 20 VDC to 40 VDC
Input Range (Full Power): VDC
Transient Survival Voltage: VDC
Isolation Input to Case: VDC
Isolation Input to Output: VDC
Isolation Output to Case: VDC
Storage Temp: -55 °C to 150 °C
Shock: 20 G's
Acceleration: G's
Vibration: 12 G's
Weight: 1200 gms typical

Environment

Grade EU:
Full Output Power at Tcase = 85°C
Minimum Output Power at Tcase = -55°C
Linearly derates to zero at Tcase = 115
TID up to kRad(Si)
No SEE up to 60MeV*cm2/mg
Grade L:
Full Output Power at Tcase = 85°C
Minimum Output Power at Tcase = -55°C
Linearly derates to zero at Tcase = 115
TID up to 45kRad(Si)
No SEE up to 60MeV*cm2/mg
Grade LE:
Full Output Power at Tcase = 125°C
Minimum Output Power at Tcase = -55°C
Linearly derates to zero at Tcase = 135
TID up to 45kRad(Si)
No SEE up to 60MeV*cm2/mg
Grade S:
Full Output Power at Tcase = 85°C
Minimum Output Power at Tcase = -55°C
Linearly derates to zero at Tcase = 115
TID up to 100kRad(Si)
No SEE up to 60MeV*cm2/mg
Grade SE:
Full Output Power at Tcase = 125°C
Minimum Output Power at Tcase = -55°C
Linearly derates to zero at Tcase = 135
TID up to 100kRad(Si)
No SEE up to 60MeV*cm2/mg

Additional Notes

Ultra-Low Vf Input Reverse Polarity protection: Protects against input misconnections or unanticipated polarity reversal of any duration. Clampless design eliminates need for external diodes or fuses.

Input Under Votlage Lockout: User programmable UV lock with hysteresis to hut operation at line inputs under selected limit.

Remote Sense: Auto adjusts output voltage for load lead losses

Output Soft Start: User programmable output turn on delay ramp.

Full Load Range Voltage Regulation: Regulates down to zero applied load.

Dual Mode Overcurrent Short Circuit Protection: Current mode control pulse by pulse and cyclic mode overcurrent protection.

Internal OverVoltage Protection: Overvoltage protected for internal (open control loop) fault.

Built in EMI filter: Input filer, output filtering smooth ripple and attenuates noise spikes.


Warning: Uninitialized string offset 0 in /home/mdipower/www/www/wp-content/themes/mdipower-2025/functions.php on line 337

Single Output Devices

Parameters Conditions 53696-S12 (500W)
MIN TYP MAX
Output set voltage 12.0
Output current 42A
Efficiency Pout = max rated load 84%
Line regulation 2%
Output ripple F.L. BW 2 MHz
mVpp
120