100 Watt Hybrid DC-DC Converter
| Parameters | Conditions | 7031A-S05 (100W) MIN | 7031A-S05 (100W) TYP | 7031A-S05 (100W) MAX |
|---|---|---|---|---|
| Output Voltage (FLD) | — | +4.9 | +5.0 | +5.1 |
| Output current | Vin min — Vin max | - | - | 20A |
| Efficiency | Pout = max rated load | 70% | 73% | - |
| Line regulation | Pout = max rated load Vin min — Vin max |
- | 10mV | 50mV |
| Load regulation | Pout = 10% to F.L. | - | 10mV | 50mV |
| Output ripple | F.L. BW 2 MHz mVpp |
- | 40 | 85 |
| 7031A-SXX<24 |
|---|
| Pin-1: Bit |
| Pin-2: Inhibit Not |
| Pin-3: Soft Start |
| Pin-4: Sync |
| Pin-5: + Input |
| Pin-6: Input ret |
| Pin-7: N/C |
| Pin-8: Main Output |
| Pin-9: Main Output Ret |
| Pin-10: + Remote Sense |
| Pin-11: Adjust |
| Pin-12: - Remote sense |